Skip to main content
Licensed & Insured · CSLB #1077447
Manual J load calculation report
ACCA Compliant
48-Hour Delivery

Free for Builders, GCs & Homeowners

Most HVAC Systems Are Improperly Sized.
Yours Won't Be.

Upload your blueprints. Get a free, ACCA-compliant Manual J report with equipment sizing and duct design — delivered in 48 hours.

Other companies charge $300–$800 for this. We do it free because every building deserves properly sized equipment — and we'd rather earn your business through competence.

The Hidden Cost of Guesswork

50% of HVAC Systems in the U.S. Are Oversized. Here's Why That Costs You.

Without a proper Manual J calculation, most contractors use "rule of thumb" sizing — 400–500 sq ft per ton. That method ignores insulation, windows, orientation, duct losses, and local climate data. The result? Equipment that's too big, too expensive, and fails too soon.

Higher Energy Bills

Oversized systems short-cycle — turning on and off rapidly instead of running efficient, steady cycles. This wastes 20–30% more energy than a properly sized system.

Humidity & Comfort Issues

Short-cycling means the system never runs long enough to dehumidify. You end up cold and clammy, or constantly adjusting the thermostat.

Premature Equipment Failure

Constant on/off cycling wears out compressors, contactors, and fan motors years before their rated lifespan. You're replacing a $15K system in 8 years instead of 15.

Simple 3-Step Process

Upload. Calculate. Build Right.

We use ACCA-approved methodology powered by AutoHVAC.ai to deliver professional-grade load calculations faster than anyone in the industry.

01

Upload Your Plans

Submit your blueprint or architectural drawing (PDF, DWG, DXF, JPG, PNG) along with the project zip code. That's all we need to get started.

02

We Run the Numbers

Our team processes your plans through ACCA-compliant Manual J methodology, factoring in construction type, insulation, windows, orientation, and local climate data.

03

Get Your Report

Within 48 hours, you receive a professional PDF report with load calculations, equipment sizing (Manual S), and duct design guidance (Manual D).

Your Report Includes

Not Just a Number. A Complete Engineering Package.

Manual J Load Calculation

Room-by-room heating and cooling load analysis based on your building's actual construction.

Equipment Sizing (Manual S)

Specific equipment recommendations matched to your calculated loads — not guesswork.

Duct Design Guidance (Manual D)

CFM requirements per room, duct sizing recommendations, and static pressure budgets.

Climate-Specific Data

Calculations use ASHRAE design conditions for your exact zip code — not regional averages.

Professional PDF Report

A clean, presentation-ready document you can share with inspectors, builders, or homeowners.

Equipment Options

Multiple equipment options at different price points so you can make informed decisions.

Built for Everyone Who Builds

Whether You're Building New or Replacing Old

Builders & GCs

Get accurate load calcs for every project. Pass inspection first time. Differentiate your builds with properly sized HVAC.

Architects

Integrate HVAC sizing into your design phase. Avoid costly change orders from improperly sized mechanical systems.

Homeowners

Make sure your new system is the right size. Stop paying for oversized equipment that wastes energy and fails early.

Developers

Scale load calculations across multi-unit projects. Get consistent, professional reports for every unit in the development.

Get Started — It's Free

Upload Your Plans. Get Your Report in 48 Hours.

No payment required. No obligation. Just accurate load calculations.

Click to upload your blueprint

PDF, DWG, DXF, JPG, or PNG — up to 100MB

Project Details

No payment required. Your report will be delivered via email within 48 hours.

What to Expect

Upload plans → receive calculations within 48 hours

100% remote — no site visit required for plan-based calcs

ACCA-compliant calculations you can submit to permitting

Detailed load report with equipment sizing recommendations

Honest assessment guarantee: If we inspect your system and determine you don't need a Manual J calculation, we'll tell you. We'd rather earn your trust than your money.

Real Results

What Our Clients Say About Proper Load Calculations

Google Review

"Three other HVAC companies told us we needed a 5-ton unit. Breezy ran the Manual J and proved we only needed 3.5 tons. Saved us thousands on the equipment AND our energy bills are lower. This is what honest HVAC looks like."

T

The Rodriguez Family

Irvine \u00b7 Manual J · Right-Sizing

Google Review

"We've used Breezy on three custom builds now. They show up prepared, coordinate with our trades, and the systems pass inspection first time. Their Manual J calculations are the reason our HVAC designs work from day one."

D

David K.

Laguna Beach \u00b7 Builder · Load Calcs

Google Review

"Our new home had hot and cold spots everywhere. Breezy ran a proper load calculation and found the original installer oversized the system by 40%. After right-sizing, every room is comfortable for the first time. I wish we'd found them sooner."

P

Patricia W.

Dana Point \u00b7 Homeowner · Comfort

Common Questions

Manual J FAQ

Stop Guessing. Start Calculating.

Every improperly sized system costs thousands in wasted energy, comfort problems, and premature failure. Get the math right — for free.